Temtop P600 Air Quality Laser Particle Detector

Temtop P600 Air Quality Laser Parti

Product Overview: 
Laser particle detector can accurately detect indoor air quality. Adopting laser particle sensor, it can directly transform the concentration of pollutants in the air into visual data and provide air quality for you to effectively safeguard the health of your family.

Application Scope:
At home, office, cab , etc.

Product Specifications:
Name: Laser Particle Detector
Model: P600
Display mode: TFT Color LCD Screen
Battery voltage: 3.7VDC
Overall dimension: 177*65.5*32 mm
Power adapter: Output voltage: DC5V; Output current: 1A
Operating environment: Temperature range: 0-50℃; Humidity range: 0-90% RH; Atmospheric pressure condition:  1atm
PM2.5/10 measurement technical index: Range: 0-999ug/ m³; Resolution: 0.1ug/m³
Health Standard Index:


        Status
Monitor
Good Normal Hazardous
PM2.5 <75 75~200 >200
PM10 <100 100~200 >200

Operation Method: 
1. Turn on/off the detector: 
Press and hold the power button for 2 second to turn on/off the detector. No operation for 1h, it will turn off too, except for the recording curve display interface.
2. Detect the concentration of PM2.5, PM10 
Turn on the detector and put it in the environment which needs testing, then the system will automatically detect the concentration of PM2.5, PM10.
3. Power indication:
The detector has the function of testing the battery power. When it is , the battery is full; When it shows , the battery is low. Please charge.
4. Switch of display content
PM2.5 Button: Press it and the system will enter PM2.5 index display interface.
PM10 Button: Press it and the system will enter PM10 index display interface.
Curve Button: Press it and then the system will enter PM2.5 recording curve display interface.
Play/Stop Button: Under the mode of "Running", if you press it, the system will enter detection-pause mode and all values are maintained; Under the mode of "Hold", if you press this button, the system will reenter real time detection mode.

Operation Notice: 
1. The sensor used to detect PM2.5, PM10 adopts laser detection theory, so objects like battings and hair should be prevented from entering the detector to avoid influencing the accuracy of test data.
2. Don not put the detector in the environment where the concentration of particles is more than 500ug/m³ for long time. Long-time exposure to high-concentration air pollutants will damage the sensor and make it work improperly.
3. Avoid using the detector in humid environment to make sure the accuracy of test data.
4. Avoid bump, strike and drop.
5. Do not cover the detection port and air outlet port when using the detector.
6. Be cautious of cross interference.

Packing List:
Main machine………………………………………………………1 Set
USB cable………………………………………………………………1 Piece
User manual……………………………………………………………1 Piece