Product Overview 

 The DR-230 series is a large-screen temperature and humidity recorder, which is used for real-time monitoring and recording of ambient temperature and humidity, and supports functions such as over-limit alarm and historical data upload. The recorder is mainly composed of an external temperature and humidity sensor and host equipment. Users interact with the recorder through Elitech iCold Cloud APP. The operating parameters of the recorder can be set through the APP, including temperature unit, time zone, recording interval, alarm switch, alarm parameters, sensor type, etc. The recorded data stored in the recorder can be read through the APP and automatically uploaded to the cloud. The historical data can be read through the APP for report export and other operations. The product is widely used in industrial workshops, warehouses and other scenarios.

1. Product features

• Fashion design supports wall mounting, tabletop and other placement methods  

• Large-size display panel, clear and rich content display  

• Bluetooth communication, free from communication costs  

• 30000 sets of data local storage, supports cyclic storage  

• Local sound and light alarm, timely over-limit notification  

• Suitable for warehouses, workshops and other occasions

 

2. Product interface

Measurement Channel:  

When the device is configured with an external sensor type:  

1. The data of the first external T/H sensor is displayed.  

2. The data of the second external T/H sensor is displayed.  

When the device is configured as the built-in sensor type, the channel is not displayed, and the current display data is from the built-in sensor.

 

Alarm Display:  

When any measured temperature or humidity value exceeds the set limit, the device screen flashes at 1-second intervals.  

When the measured value returns to within the normal range, the device automatically restores to a steady display.

3. Product structure

4. Selection list

5. Technical specifications

1.  Power Input: 5V/2A

2.  Temperature Display Resolution: 0.1°C

3.  Humidity Display Resolution: 0.1% RH

4.  Number of Recording Groups: 30,000 groups

5.  Data Storage: Cyclic storage

6.  Recording Interval: Configurable from 10 seconds to 24 hours (default: 10 minutes)

7.  Alarm Parameters: 3 seconds / 10 seconds / constant ringing (default: off)

8.  Screen: Plexiglass panel

9.  Communication Method: Bluetooth

10. Alarm Mode: External alarm with flashing display

11. Protection Level: IP50

12. Dimensions: 215mm × 165mm × 19mm


Manual

Peripheral connections

According to the interface icons on the back of the recorder, connect the corresponding peripherals (power supply, sensor, alarm).

Power supply

Use the standard power cord to connect the recorder to power supply. The device will turn on automatically after powering up.

 

Configuration

Use the Elitech iCold APP to set the recorder parameters.

 Alarm

1. The Elitech iCold APP can be used to configure device alarm parameters, including:

   - Temperature alarm upper limit

   - Temperature alarm lower limit  

   - Humidity alarm upper limit

   - Humidity alarm lower limit

   - Alarm mode

   - Alarm switch

   - Other parameters

 

2. When any temperature or humidity measurement parameter exceeds the limit:

   - The device screen flashes at 1-second intervals

   - When values return to within the normal range, the device automatically restores to normal display

 

3. Alarm delay function:

   - When any parameter exceeds the limit, the device starts timing according to the alarm delay setting

   - If values do not return to normal within the delay period, the device triggers the external acousto-optic alarm according to the set alarm mode after the delay time elapses


APP Manual

  1. Sign in

Please scan the QR code on the front page of this manual or search for "Elitech iCold" in the mobile app store to download and install. After installation, open the APP and follow the prompts to register and log in.

2. Add device

After  login, the  display  is  as  follows:

Click"" in the upper left corner of the home page,

Click Bluetooth Data Logger. Go to the device classification screen, Logger and adddevice

Swipe up and down to select the device, or tap the icon in the upper right corner to scan the barcode on the back of the device. After selecting the device to connect, choose "Config" to configure parameters once the connection is successful. When re-entering the interface, tap "Read data". Once the data is successfully read, the device will be added automatically.

3. Parameter setting

After the above parameters are set, click "OK" in the upper right corner of the interface to complete the parameter delivery. After the parameters are successfully delivered, the setting will automatically start recording.

 

4. Enable/stop recording

① Enable recording: After you tap OK on the parameter setting screen, the device starts recording data.

② Stop recording: click "Read data" to enter the data interface, and click " " in the upper right corner to stop recording.

 

Note: After manually stopping the record, you need to reconfigure the parameters to turn on the record again.

Note: After manually stopping the record, you need to reconfigure the parameters to turn

on the record again.

 

5. View the data

 In the recorder connection after the successful pop-up interface, click "Read data", automatically read the recorder stored data, read the data after the completion of the data display, support charts and detailed data two display modes. In the detailed data display interface, you can export the report operation. 

 In the "Nearby" interface, click "Cloud" below to enter the cloud data view. On the interface, you can click the historical trip to view the corresponding data and export the data report.

6. Check the device status

① "Record": The device is in the record state; 

② "Stopped": the device is in the stopping state;

Please type in URL http://new.i-elitech.com to log in for more operation. Click“Help” to obtain Cloud and App operation instructions.

 